Automatic Operation (Synchronous Control)
9-30
9.6.3 Cam Pattern Setting Method
The following procedure is explained on the condition that CMI has already started.
Starting Cam pattern setting screen
Select "Parameter" > "Cam pattern settings" from the menu bar. The cam patter setting
screen is displayed. A blank screen is displayed for a new file, and a setting of cam pattern 1
is displayed when data already exists.
Resolution setting
Press the [Resolution] button on the Cam Pattern screen. The Resolution Settings screen will
be displayed. Select the desired resolution and press the [OK] button.
Resolution
AFP7MC16EC AFP7MC32EC AFP7MC64EC
1024, 2048, 4096, 8192 1 to 64 1 to 128 1 to 256
16384 1 to 32 1 to 64 1 to 128
32768 1 to 16 1 to 32 1 to 64