16.5 Unit Memories (Common Area)
16-37
16.5.4 Axis Group Setting Area
: Available, -: Not available
Axis no.
Unit
memory
no. (Hex)
Name Default Description R W
1-16 UM 00490
Interpolation
group 1
setting
H0
Set either independent or interpolation for
each axis in this area. In case of interpolation,
each axis belongs to any group 1 to 32. For
example, the axes 1, 2 and 3 belong to group
1 and are 3-axis interpolation, set the
corresponding 3 bits to on (1) in the
interpolation axis setting of group 1.
In the case of single axis independent setting,
set the corresponding bits to off (0).
Maximum number of interpolation axis per
group is 3. The same axis cannot be set in
more than one group.
17-32 UM 00491
33-48 UM 00492
49-64 UM 00493
Virtual 1-16 UM 00494
Virtual 17-32 UM 00495
-
UM 00496
-UM 00549
For interpolation groups 2 to 31, 6 words are allocated to each group.
1-16 UM 0054A
Interpolation
group 32
setting
H0 Same as above.
17-32 UM 0054B
33-48 UM 0054C
49-64 UM 0054D
Virtual 1-16 UM 0054E
Virtual 17-32 UM 0054F
1-16 UM 00550
Independent
axis setting
H0
The bit corresponding to the axis is;
0: Belongs to interpolation group or the axis is
not set as a used axis.
1: Independent (Not belong to interpolation
group)
An error occurs when this overlaps with the
setting of interpolation group.
17-32 UM 00551
33-48 UM 00552
49-64 UM 00553
Virtual 1-16 UM 00554
Virtual 17-32 UM 00555
-
UM 00556
-UM 0058F
Reserved for
system
- -
- -
(Note 1): Bits for 16 axes are allocated to each area (1 word).
bit no.
15 08 7
9 1816
Axis no.
25 172432
41 334048
57 495664