Loading...
5.4 Synchronous Parameter and Cam Pattern Settings
5-17
5.4 Synchronous Parameter and Cam Pattern Settings
5.4.1 Synchronous Parameter Settings
Parameters required for the synchronous control are assigned using CMI. The following
procedure is explained on the condition that CMI has already started. The synchronous
parameter setting is made for slave axes.
PROCEDURE
1. Select and double-click the axis for setting the parameters from the project
tree.
The synchronous parameter dialog box is displayed.
2. Set necessary parameters in accordance with the intended use.
REFERENCE
For details of the methods of setting parameters related to synchronous
control, refer to "9 Automatic Operation (Synchronous Control)".