Settings of FP7 MC Unit
Using CMI Tool
5-8
5.2.3 Axis Parameters (Options)
These parameters are set according the used functions.
Software limit setting
Parameter name
Default
Description
Software limit (Positioning
control)
UM 0324B bit0
N: Disabled
Select whether to enable or disable the software limit when
executing the positioning control, home return or JOG
operation.
N: Disabled, A: Enabled
Software limit (Home return)
UM 0324B bit1
N: Disabled
Software limit (JOG operation)
UM 0324B bit2
N: Disabled
Software limit Upper limit value
UM 0324C - UM0324D
2147483647
Set the upper or lower limit of the software limit.
Software limit Lower limit value
UM 0324E - UM 0324F
-2147483648
(Note): The values set in these parameters are stored in the unit memory numbers described below the parameter
names.
Auxiliary output setting
Parameter name Default Description
Auxiliary output mode
UM 03252 bit7-0
N: Not used
Select the operation mode of auxiliary output contact and
auxiliary output code.
N: Not used, W: With mode, D: Delay mode
Auxiliary output ON time (ms)
UM 03252 bit15-8
10
Set the time period that auxiliary output contact is ON.
Range: 0 to 255 ms
Auxiliary output delay ratio (%)
UM 03253
0
When using the delay mode for the auxiliary output, specify
the ratio to output.
Range: 0 to 100 %
(Note): The values set in these parameters are stored in the unit memory numbers described below the parameter
names.