5.2 Axis Parameter Settings
5-9
Monitor setting
Parameter name
Default
Description
Movement check operation
UM 0324A
2: None
Select the operation when exceeding the movement amount
automatic check threshold.
0: Error, 1: Warning, 2: None
Movement check value (pulse)
UM 03258-UM 03259
10000
Set the threshold for the movement amount automatic check
operation. (Note)
Extend
monitor value
Range
1 word 0 to 65535 pulses
2 words 0 to 2147483647 pulses
Completion width check time
(ms)
UM 03257
0
Specify the width of the completion of command operation.
When "0" is set, the completion width is not checked.
Range: 0 to 10,000 ms
Completion width (pulse)
UM 0325A-UM 0325B
10
Turns on the completion flag when the AMP current value
[feedback value] becomes within this completion width after
the movement of a set amount during the positioning control,
JOG operation.
Range: 1 to 2,147,483,647
Any other settings will be errors.
Monitor error
- Torque judgement
UM 0325C bit1-0
N: Disabled
Select the operation of FP7 MC Unit when the torque value of
the amplifier is monitored and exceeds the judgement value.
N: Disabled, E: Enabled (Error), W: Enabled (Warning)
Monitor error-
Torque judgement value (%)
UM 0325D
5000
Set the torque judgement value.
Range: 0 to 5000 (0.0 % to 500.0 %)
Monitor error
- Actual speed judgement
UM 0325C bit3-2
N: Disabled
Select the operation of FP7 MC Unit when the actual speed of
the amplifier is monitored and exceeds the judgement value.
N: Disabled, E: Enabled (Error), W: Enabled (Warning)
Monitor error -
Actual speed judgement value
unit
UM 0325C bit4
0: 0.1 rpm
When "2 words" is set for "Extend monitor value", set the unit
for the monitor error actual speed judgement. (Note)
0: 0.1 rpm
1: Command unit/s
Monitor error
- Actual speed judgement value
UM 0325E-UM 0325F
5000
Set the actual speed judgement value. (Note)
Extend
monitor value
Monitor error
unit
Range
1 word 1 rpm 0 to 5000 rpm
2 words 0.1 rpm 0 to 6500.0 rpm
Command
unit/s
2147483647 command
unit/s
(Note): The values set in these parameters are stored in the unit memory numbers described below the parameter
names.
REFERENCE
For details of each function of software limit, auxiliary output and monitor
setting, refer to "13 Supplementary Functions".
For details of the "Extend monitor value" setting, refer to "5.1.2 FP7 MC Unit
Common Settings Parameters".