16.5 Unit Memories (Common Area)
16-45
16.5.11 Warning Annunciation and Clear Area
●: Available, -: Not available
Axis no.
Unit
(Hex)
Name Default Description R W
-
UM 01710
-UM 01715
Reserved
for system
- - - -
1-16 UM 01716
Warning
clear
individual
axis setting
H0
Clears the FP7 MC Unit warning of the axis for
the corresponding bit.
After changing the corresponding bit to 1, FP7
MC Unit clears the corresponding bit to 0
automatically.
17-32 UM 01717
33-48 UM 01718
49-64 UM 01719
Virtual 1-16 UM 0171A
Virtual 17-32 UM 0171B
-
UM 0171C
-UM 0173F
Reserved
for system
- - - -
(Note 1): Bits for 16 axes are allocated to the warning clear individual axis setting area (1 word).
bit no.
15
0
8 7
9 1816
● ● ● ● ● ●● ● ● ● ● ●
Axis no.
25 172432
● ● ● ● ● ●● ● ● ● ● ●
41 334048
● ● ● ● ● ●● ● ● ● ● ●
57 495664
● ● ● ● ● ●● ● ● ● ● ●