CMTimeChart Monitor
14-16
Unit memories (Time chart function operation setting/annunciation area)
●: Available, -: Not available
Axis
no.
Unit
memory
no. (Hex)
Name Default
Description R W
- UM 02630
Announce trigger
registration
H0
When a trigger condition has been registered in FP7
MC Unit, the bit corresponding to the trigger number
turns on.
0Not registered
1: Trigger condition is registered.
-
- UM 02631 Allow trigger use H0
For allowing the use of a trigger by a user program,
turn the bit corresponding to the trigger number.
0Not allow the use.
1: Allow the use.
- UM 02632 Logging flag H0
It turns on when the logging operation is being
executed on FP7 MC Unit. It turns off when the
logging operation is complete.
0Logging is not executed / complete.
1: During logging
-
- UM 02633
Presence/absence
of logging data
H0
It turns on when the logging operation is complete
on FP7 MC Unit and logging data exists.
0No logging data
1: Logging data exists.
-
(Note 1): Sixteen bits corresponding to respective trigger numbers are allocated to the time chart function operation
setting/annunciation area (1 word).
bit no.
15
0
8 7
9 1816
Trigger no.