16.8 Unit Memories (Synchronous Control Setting Area)
16-79
●: Available, -: Not available
Axis no.
Unit
memory
no. (Hex)
Name Default
Description R W
1 UM 63F70
Clutch ON
method
H0
Select the clutch ON method.
H0: Direct
H1: Slip
1 UM 63F71
Reserved for
system
- - - -
1 UM 63F72
Clutch ON
slip method
H0 H0: Slip time setting
1 UM 63F73
Clutch ON
slip time
U1
Set a slip time when the clutch ON method is set to
"H1: Slip".
1 to 10,000 [ms]
1
UM 63F74
-UM 63F75
Reserved for
system
- - - -
1 UM 63F76
Clutch ON
slip curve
selection
H0 H0: Linear
1
UM 63F77
-UM 63F7F
Reserved for
system
- -
- -
1 UM 63F80
Clutch OFF
method
H0
Select the clutch OFF method.
H0: Direct
H1: Slip
1 UM 63F81
Reserved for
system
- - - -
1 UM 63F82
Clutch OFF
slip method
H0 H0: Slip time setting
1 UM 63F83
Clutch OFF
slip time
U1
Set a slip time when the clutch OFF method is set
to "H1: Slip".
1 to 10,000 [ms]
1
UM 63F84
-UM 63F85
Reserved for
system
- -
- -
1 UM 63F86
Clutch OFF
slip curve
selection
H0 H0: Linear
1
UM 63F87
-UM 63F8F
Reserved for
system
- - - -
(Note): The above table shows the unit memory numbers of axis number 1. For details of the whole configuration,
refer to "16.8.1 Configuration of Synchronous Control Setting Area".