Automatic Operation (Synchronous Control)
9-38
The parameters used for the cam pattern editing with user programs are as follows.
Axis
no.
Unit
memory
no. (Hex)
Name Default
Unit Setting range and description
- UM 66F40
Cam
pattern
no.
U0
When reading: Set a cam pattern number to be read out.
When rewriting: Set a cam pattern number to be written.
bit Pattern resolution
Setting range
Axis 16
Axis 32
Axis 64
15-0
1024,2048,4096,8192 1 to 64
1 to
128
1 to
256
16384 1 to 32 1 to 64
1 to
128
32768 1 to 16 1 to 32 1 to 64
Any other settings will be errors.
- UM 66F41
Reserved
for system
-
-
- UM 66F42
No. of
cam
pattern
setting
sections
U0 Section
When reading, the number of setting sections of the read cam
pattern table is stored.
When rewriting, the cam curve number of the rewritten cam
pattern table is set.
bit Name Description
15-0
No. of cam
pattern setting
sections
Setting range: 1 to 20 (sections)
Any other settings will be errors.
- UM 66F43
Shift
amount
U0 0.01%
When reading, the shift amount of the read cam pattern table
is stored.
When rewriting, the shift amount of the rewritten cam pattern
table is stored.
bit Name Description
15-0 Shift amount
Range: 0 to 100.00 (%)
Any other settings will be errors.