Loading...
Automatic Operation (Synchronous Control)
9-54
Setting with tool software
Set in the synchronous control setting dialog box.
Parameter name
Overview
Advance angle
correction operation
setting
Select the use or non-use of the advance angle correction function.
Advance angle
correction
reference amount
When using the advance angle correction function, set the correction reference amount
used by FP7 MC Unit for calculating the advance angle correction amount.
The unit follows the unit system of the master axis.
Setting range: -2147483648 to 2147483647 (The decimal point position is based on
unit systems.)
Advance angle
correction
reference speed
When using the advance angle correction function, set the reference speed used by
FP7 MC Unit for calculating the advance angle correction amount.
The unit follows the unit system of the master axis.
Setting range: 1 to 2147483647 (The decimal point position is based on unit systems.)
Advance angle
correction
parameter change
time
Set the time required until a changed value is reflected when the parameter related to
the advance angle correction is changed during the electronic cam operation.
Setting range: 1 to 10000 ms
Setting with user programs
The following example shows the case that the advance angle correction reference amount of
1st axis is changed to 50 and the advance angle correction reference speed to 3000.
R0
DF
MV.SL
S1:UM63F96
K50
DF
MV.SL
S1:UM63F98
K3000
R1