16.4 Unit Memories (Input and Output Control Areas)
16-15
: Available, -: Not available
Axis no.
Unit
memory
no. (Hex)
Name Default Description R W
1-16 UM 0009C
Home return
done
H0
When the home return operation is completed,
the bits corresponding to each axis number
turn on. After this flag turns on, the on state
will continue until the next control is activated.
-
17-32 UM 0009D
33-48 UM 0009E
49-64 UM 0009F
Virtual 1-16 UM 000A0
Virtual 17-32 UM 000A1
1-16 UM 000A2
Near home
input
H0
Monitor flag for the near home input connected
to the corresponding AMP.
[The update cycle is communication
(EtherCAT communication) cycle.]
-
17-32 UM 000A3
33-48 UM 000A4
49-64 UM 000A5
-
UM 000A6
-UM 000AB
Reserved for
system
- - - -
1-16 UM 000AC
Auxiliary
contact
H0
This contact is enabled when the auxiliary
output function has been set.
When the positioning table is executed, the
bits corresponding to each axis number turn
on.
The ON time and delay ratio depends on the
contents specified in the axis parameter.
-
17-32 UM 000AD
33-48 UM 000AE
49-64 UM 000AF
Virtual 1-16 UM 000B0
Virtual 17-32 UM 000B1
(Note 1): Flags for 16 axes are allocated to each area (1 word).
bit no.
15
0
8 7
9 1816
Axis no.
25 172432
41 334048
57 495664

Table of Contents