Remote Control Commands
R&S
®
SMB100A
390Operating Manual 1407.0806.32 ─ 21
[:SOURce<hw>]:PULM:DELay........................................................................................ 390
[:SOURce<hw>]:PULM:DOUBle:DELay............................................................................391
[:SOURce<hw>]:PULM:DOUBle:STATe........................................................................... 391
[:SOURce<hw>]:PULM:DOUBle:WIDTh........................................................................... 391
[:SOURce<hw>]:PULM:MODE........................................................................................ 391
[:SOURce<hw>]:PULM:OUTPut:SYNC[:STATe]................................................................392
[:SOURce<hw>]:PULM:PERiod....................................................................................... 392
[:SOURce<hw>]:PULM:POLarity..................................................................................... 393
[:SOURce<hw>]:PULM:SOURce..................................................................................... 393
[:SOURce<hw>]:PULM:STATe........................................................................................394
[:SOURce<hw>]:PULM:TRAin:CATalog?..........................................................................394
[:SOURce<hw>]:PULM:TRAin:DELete............................................................................. 394
[:SOURce<hw>]:PULM:TRAin:OFFTime.......................................................................... 395
[:SOURce<hw>]:PULM:TRAin:OFFTime:POINts?............................................................. 395
[:SOURce<hw>]:PULM:TRAin:ONTime............................................................................ 396
[:SOURce<hw>]:PULM:TRAin:ONTime:POINts?...............................................................396
[:SOURce<hw>]:PULM:TRAin:REPetition.........................................................................397
[:SOURce<hw>]:PULM:TRAin:REPetition:POINts?............................................................397
[:SOURce<hw>]:PULM:TRAin:SELect..............................................................................398
[:SOURce<hw>]:PULM:TRIGger:EXTernal:GATE:POLarity................................................ 398
[:SOURce<hw>]:PULM:TRIGger:EXTernal:IMPedance......................................................399
[:SOURce<hw>]:PULM:TRIGger:EXTernal:SLOPe............................................................399
[:SOURce<hw>]:PULM:TRIGger:MODE........................................................................... 399
[:SOURce]:PULM[:INTernal][:TRAin]:TRIGger:IMMediate...................................................400
[:SOURce<hw>]:PULM:TRAin:DEXChange:AFILe:CATalog?............................................. 400
[:SOURce<hw>]:PULM:TRAin:DEXChange:AFILe:EXTension............................................401
[:SOURce<hw>]:PULM:TRAin:DEXChange:AFILe:SELect................................................. 401
[:SOURce<hw>]:PULM:TRAin:DEXChange:AFILe:SEParator:COLumn...............................402
[:SOURce<hw>]:PULM:TRAin:DEXChange:AFILe:SEParator:DECimal............................... 402
[:SOURce<hw>]:PULM:TRAin:DEXChange:EXECute........................................................403
[:SOURce<hw>]:PULM:TRAin:DEXChange:MODE............................................................403
[:SOURce<hw>]:PULM:TRAin:DEXChange:SELect...........................................................404
[:SOURce<hw>]:PULM:WIDTh........................................................................................404
[:SOURce<hw>]:PULM:DELay <Delay>
Sets the pulse delay.
Parameters:
<Delay> float
Range: 0 to 100 s
Increment: 10 ns
*RST: 10 ns
Example:
PULM:DEL 13 us
13 us elapse after a trigger before the first pulse is generated.
Options: R&S R&S SMB-K23 (Pulse Generator)
Manual operation: See "Pulse Delay - Pulse Generator" on page 228