SERVICE PROGRAM MODE
C262/C265 5-44 SM
5: 6-2 (Master making density)
0: Pale, 1: Normal, 2: Dark
The default is 1: Normal. Changing this moves the user’s image density settings up
or down one notch.
Density -2 -1 0 1 2 3
0 Pale Normal Little Dark Dark
1 Pale Normal Little Dark Dark
2 Pale Normal Little Dark Dark
6: 6-3-1 (Drum master clamper registration)
This determines how far after the leading edge the master is clamped.
A larger value clamps the master further away from the leading edge, and moves
the image closer to the leading edge of the paper.
Do not use this SP to adjust leading edge registration. Use SP6-1-3 and -4 for that.
7: 6-4-7 (List of Sensor Adjustments)
A list of the following sensor adjustments is displayed.
• Master End Sensor (ROLL)
• Master Eject Sensor (EJCT)
• Master Edge Sensor (TOP)
• Master Set Sensor (SET)
• 1
st
Drum Master Sensor (MST1)
• 2
nd
Drum Master Sensor (MST2)
The voltage output from the sensors is shown in the top line of the display. You can
use the + and – buttons on the right side of the display to adjust the boundary
conditions for On or Off on the bottom line of the display.
When you are checking the master edge sensor, you must push the Start key to
open the master buffer duct entrance plate. The duct plate will stay open for 30
seconds, then it will close automatically. If you want to close the plate before 30
seconds, press the Start key again. When the plate is open, ‘TOP’ will be shown on
the display as white-on-black.