2-130 Parameter Descriptions
7000-TD002A-EN-P – September 2007
Local Command Mask [Local Mask]
Linear Number: 242
Default Value: 11111111
Access Level: Basic
Read/Write: Read/Write
This parameter specifies which adapters can issue the local command. A one represents the adapter that
can issue the local command, a zero represents an adapter that cannot issue the local command. There
are 8 adapters available, from Adapter0 to Adapter7.
Bit Enum Text Description
0 Adapter 0 Host
1 Adapter 1
2 Adapter 2
3 Adapter 3 (Currently unused)
4 Adapter 4 (Currently unused)
5 Adapter 5
6 Adapter 6 (Currently unused)
7 Adapter 7 (Currently unused)
Logic Command Mask [Logic Mask]
Linear Number: 241
Default Value: 11111111
Access Level: Basic
Read/Write: Read/Write
This parameter specifies which adapters can issue the logic command. A one represents the adapter that
can issue the logic command, a zero represents an adapter that cannot issue the logic command. There
are 8 adapters available, from Adapter0 to Adapter7.
Bit Enum Text Description
0 Adapter 0 Host
1 Adapter 1
2 Adapter 2
3 Adapter 3 (Currently unused)
4 Adapter 4 (Currently unused)
5 Adapter 5
6 Adapter 6 (Currently unused)
7 Adapter 7 (Currently unused)