Instrument Functions
R&S
®
FSVA/FSV
513Operating Manual 1176.7510.02 ─ 09
Example 1:
SOURce:EBOX:*RST
SOURce:EBOX:*IDN?
Result:
"Rohde&Schwarz,DigIConf,02.05.436 Build 47"
Example 2:
SOURce:EBOX:USER:CLOCk:REFerence:FREQuency 5MHZ
Defines the frequency value of the reference clock.
3.7.5 Interface Status Information
When a digitial input or output device is connected to the R&S Digital I/Q Interface, a
dialog box and status icons in the status bar provide information on the status of the
connection. To display the dialog box, select the "Digital IQ Info" softkey in the "Input/
Output" menu (see "Digital IQ Info" on page 432).
The following information is displayed:
Table 3-19: Displayed Information for Digital Baseband Connections
Label Description
Digital I/Q input connection
Digital-I/Q Input Device connected to R&S FSVA/FSV input interface
Serial Number Serial number of the connected device
Port Port name used by the connected device
(Max.) Digital Output Sample
Rate
Maximum possible or currently used sample rate of the connected device;
depends on the used connection protocol version (see "<SampleRate-
Type>" parameter described in INPut:DIQ:CDEVice on page 760)
Instrument Functions - R&S Digital I/Q Interface (Option R&S FSV-B17)