Remote Control
R&S
®
FSVA/FSV
852Operating Manual 1176.7510.02 ─ 09
Note:The measurement of the occupied bandwidth (OBW) is performed on the trace
on which marker 1 is positioned. To evaluate another trace, marker 1 must be posi-
tioned to another trace with CALCulate<n>:MARKer<m>:TRACe.
Parameters:
<TraceNumber> 1 to 6
Example:
POW:TRAC 2
Assigns the measurement to trace 2.
Manual operation: See "Select Trace" on page 331
SENSe:SWEep Subsystem
The SENSe:SWEep subsystem controls the sweep parameters.
[SENSe:]SWEep:COUNt.................................................................................................852
[SENSe:]SWEep:COUNt:CURRent?................................................................................853
[SENSe:]SWEep:EGATe................................................................................................ 853
[SENSe:]SWEep:EGATe:HOLDoff...................................................................................854
[SENSe:]SWEep:EGATe:LENGth....................................................................................854
[SENSe:]SWEep:EGATe:POLarity...................................................................................854
[SENSe:]SWEep:EGATe:SOURce...................................................................................854
[SENSe:]SWEep:EGATe:TRACe<k>:COMMent................................................................855
[SENSe:]SWEep:EGATe:TRACe<k>[:STATe<range>].......................................................855
[SENSe:]SWEep:EGATe:TRACe<k>:STARt<range>.........................................................856
[SENSe:]SWEep:EGATe:TRACe<k>: STOP<range>.........................................................856
[SENSe:]SWEep:EGATe:TRACe<k>: PERiod...................................................................856
[SENSe:]SWEep:EGATe:TYPE....................................................................................... 857
[SENSe:]SWEep:MODE................................................................................................. 857
[SENSe:]SWEep:POINts.................................................................................................858
[SENSe:]SWEep:TIME................................................................................................... 858
[SENSe:]SWEep:TIME:AUTO......................................................................................... 858
[SENSe:]SWEep:TYPE...................................................................................................859
[SENSe:]SWEep:TYPE:USED?.......................................................................................859
[SENSe:]SWEep:COUNt <NumberSweeps>
This command defines the number of sweeps started with single sweep, which are
used for calculating the average or maximum value. If the values 0 or 1 are set, one
sweep is performed.
Parameters:
<NumberSweeps> 0 to 32767
*RST: 0 (GSM: 200, PHN:1)
Example:
SWE:COUN 64
Sets the number of sweeps to 64.
INIT:CONT OFF
Switches to single sweep mode.
INIT;*WAI
Starts a sweep and waits for its end.
Remote Control – Commands