EasyManua.ls Logo

Rohde & Schwarz FSVA - 4.2.3.3 CALibration:PMETer Subsystem (Power Sensor, R&S FSV-K9); 4.2.3.4 DISPlay Subsystem

Rohde & Schwarz FSVA
1106 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote Control
R&S
®
FSVA/FSV
744Operating Manual 1176.7510.02 ─ 09
Manual operation: See "I/Q Analyzer" on page 442
See "Display Config" on page 447
4.2.3.3 CALibration:PMETer Subsystem (Power Sensor, R&S FSV-K9)
The CALibration:PMETer Subsystem determines the error correction data for measure-
ments in the power meter mode. It is only available if the R&S FSV-K9 Power Sensor
option is installed.
For details see Chapter 3.9, "Instrument Functions - Power Sensor (R&S FSV-K9)",
on page 538.
CALibration:PMETer<p>:ZERO:AUTO ONCE...................................................................744
CALibration:PMETer<p>:ZERO:AUTO ONCE
This command starts zeroing of the selected power sensor.
Note: Before starting the zeroing process disconnect all signals from the input of the
power sensor.
Suffix:
<p>
.
1...4
Power sensor index
Example:
CAL:PMET2:ZERO:AUTO ONCE;*WAI
Starts zeroing the power sensor 2 and delays the execution of
further commands until zeroing is concluded.
Mode: PSM
Manual operation: See "Zeroing Power Sensor" on page 547
4.2.3.4 DISPlay Subsystem
The DISPLay subsystem controls the selection and presentation of textual and graphic
information as well as of measurement data on the display.
Some applications offer up to four measurement windows. For those, the suffix <1....4>
for WINDow selects the measurement window. For all other applications, the suffix is
irrelevant.
DISPlay:MTABle............................................................................................................ 745
DISPlay[:WINDow<n>][:SUBWindow<m>]:SIZE................................................................745
DISPlay[:WINDow<n>][:SUBWindow<m>]:SELect.............................................................746
DISPlay[:WINDow<n>]:TRACe<t>[:STATe].......................................................................746
DISPlay[:WINDow<n>]:TRACe<t>:MODE.........................................................................747
DISPlay[:WINDow<n>]:TRACe<t>:MODE:HCONtinuous....................................................748
DISPlay[:WINDow<n>]:TRACe<t>:X:SPACing.................................................................. 748
DISPlay[:WINDow<n>]:TRACe<t>:Y:SPACing.................................................................. 749
DISPlay[:WINDow<n>]:TRACe<t>:Y[:SCALe]................................................................... 749
DISPlay[:WINDow<n>]:TRACe<t>:Y[:SCALe]:MODE.........................................................750
Remote Control – Commands

Table of Contents

Related product manuals