Instrument Functions
R&S
®
FSVA/FSV
369Operating Manual 1176.7510.02 ─ 09
Child Node Attribute Value Parameter Description Mand.
Type NORM | PULS |
CFIL | RRC
No
VBW Bandwidth <bandwidth in Hz> "VBW" on page 348 Yes
Detector
NEG | POS |
SAMP | RMS |
AVER | QUAS
If used, it has to be identical
in all ranges.
No
Sweep Mode Manual | Auto "Sweep Time Mode"
on page 348
Yes
Time <time in sec> "Sweep Time" on page 348 No
Amplitude
No
ReferenceLevel Value <power in dBm> "Ref. Level" on page 348 Yes, if the Refer-
enceLevel child
node is used
Unit dBm Defines dBm as unit Yes, if the Refer-
enceLevel node
is used
RFAttenuation Mode Manual | Auto "RF Att. Mode" on page 348 Yes, if the Refer-
enceLevel child
node is used
Preamplifier
ON | OFF "Preamp" on page 348 Yes
ASCII File Export Format (Spectrum Emission Mask)
The first part of the file lists information about the signal analyzer and the general
setup. For a detailed description refer to Chapter 3.2.8.7, "ASCII File Export Format",
on page 266.