You can read out the register with STATus:QUEStionable:LIMit<m>:
CONDition? or STATus:QUEStionable:LIMit<m>:CONDition?.
Table 4-9: Meaning of the bits used in the STATus:QUEStionable:LIMit register
Bit No. Meaning
0 LIMit 1 FAIL
This bit is set if limit line 1 is violated.
1 LIMit 2 FAIL
This bit is set if limit line 2 is violated.
2 LIMit 3 FAIL
This bit is set if limit line 3 is violated.
3 LIMit 4 FAIL
This bit is set if limit line 4 is violated.
4 LIMit 5 FAIL
This bit is set if limit line 5 is violated.
5 LIMit 6 FAIL
This bit is set if limit line 6 is violated.
6 LIMit 7 FAIL
This bit is set if limit line 7 is violated.
7 LIMit 8 FAIL
This bit is set if limit line 8 is violated.
8 to 14 Unused
15 This bit is always 0.
STATus:QUEStionable:LMARgin Register
This register contains information about the observance of limit margins.
It can be read using the commands
STATus:QUEStionable:LMARgin:CONDition? and
STATus:QUEStionable:LMARgin[:EVENt]?.
Table 4-10: Meaning of the bits used in the STATus:QUEStionable:LMARgin register
Bit No. Meaning
0 LMARgin 1 FAIL
This bit is set if limit margin 1 is violated.
1 LMARgin 2 FAIL
This bit is set if limit margin 2 is violated.
2 LMARgin 3 FAIL
This bit is set if limit margin 3 is violated.
3 LMARgin 4 FAIL
This bit is set if limit margin 4 is violated.