Remote Control Commands
R&S
®
SMB100A
413Operating Manual 1407.0806.32 ─ 13
Note: The command described here only causes a queue to be filled with data for a
specific group. The data will only be sent when the group in question is added to the
group sequence with the command "GS", on page 421.
Setting parameters:
<RetrNumb> Number of retransmissions
<DataSeq> Max. 20 different data sequences can be defined.
10 characters must be specified each per <DataSeq>. Leading
zeros, if any, must also be specified.
00: erases the data.
Range: 0000000000 to 1FFFFFFFFF (10 ASCII ccoded
hexadecimal characters each)
Parameters for setting and query:
<FFG> 1A | 3A | 5A | 6A | 7A | 8A | 9A | 10A | 11A | 12A | 13A
Determines the free format group.
To transmit the FFGs of the B group, the same commands are
used, only the A groups are replaced by the B groups in the group
sequence. If B groups are transmitted, block C is overwritten with
the PI code.
Example:
STEReo:DIRect "1A=01,0123456789,1FFFFFFFFF"
Fills a queue with the data "0123456789,1FFFFFFFFF". The data
is sent in consecutive order in group 1A after group 1A is added
to the group sequence (see command "GS", on page 421).
Example:
STEReo:DIRect? "1A"
Reads the data of group 1A.
Response: "01,0123456789,1FFFFFFFFF"
STEReo:DIRect "AF=<A>,<Freq#1>,<Freq#2>,..."
STEReo:DIRect? "AF<z>"
Defines an alternative frequency list.
Note: A maximum of five AF lists with max. 25 frequencies per list can be created.
Parameters:
<Freq> xxx.x
Sets the alternative frequencies as ASCII coded decimal numbers.
If list <z> is not available, the response is ().
Range: 87.6 to 107.9
Setting parameters:
<A> N
new AF list
+
AF list to be added