Remote Control Commands
R&S
®
SMB100A
350Operating Manual 1407.0806.32 ─ 13
[:SOURce<hw>]:PULM:OUTPut:SYNC[:STATe]................................................................352
[:SOURce<hw>]:PULM:PERiod.......................................................................................352
[:SOURce<hw>]:PULM:POLarity.....................................................................................353
[:SOURce<hw>]:PULM:SOURce.....................................................................................353
[:SOURce<hw>]:PULM:STATe........................................................................................354
[:SOURce<hw>]:PULM:TRAin:CATalog?..........................................................................354
[:SOURce<hw>]:PULM:TRAin:DELete.............................................................................354
[:SOURce<hw>]:PULM:TRAin:OFFTime..........................................................................355
[:SOURce<hw>]:PULM:TRAin:OFFTime:POINts?.............................................................355
[:SOURce<hw>]:PULM:TRAin:ONTime............................................................................356
[:SOURce<hw>]:PULM:TRAin:ONTime:POINts?...............................................................356
[:SOURce<hw>]:PULM:TRAin:REPetition.........................................................................357
[:SOURce<hw>]:PULM:TRAin:REPetition:POINts?............................................................357
[:SOURce<hw>]:PULM:TRAin:SELect..............................................................................358
[:SOURce<hw>]:PULM:TRIGger:EXTernal:GATE:POLarity................................................358
[:SOURce<hw>]:PULM:TRIGger:EXTernal:IMPedance......................................................359
[:SOURce<hw>]:PULM:TRIGger:EXTernal:SLOPe............................................................359
[:SOURce<hw>]:PULM:TRIGger:MODE...........................................................................359
[:SOURce]:PULM[:INTernal][:TRAin]:TRIGger:IMMediate...................................................360
[:SOURce<hw>]:PULM:TRAin:DEXChange:AFILe:CATalog?.............................................360
[:SOURce<hw>]:PULM:TRAin:DEXChange:AFILe:EXTension............................................361
[:SOURce<hw>]:PULM:TRAin:DEXChange:AFILe:SELect.................................................361
[:SOURce<hw>]:PULM:TRAin:DEXChange:AFILe:SEParator:COLumn...............................362
[:SOURce<hw>]:PULM:TRAin:DEXChange:AFILe:SEParator:DECimal...............................362
[:SOURce<hw>]:PULM:TRAin:DEXChange:EXECute........................................................363
[:SOURce<hw>]:PULM:TRAin:DEXChange:MODE............................................................363
[:SOURce<hw>]:PULM:TRAin:DEXChange:SELect...........................................................364
[:SOURce<hw>]:PULM:WIDTh........................................................................................364
[:SOURce<hw>]:PULM:DELay <Delay>
Sets the pulse delay. The pulse delay determines the time that elapses after a trigger
event before pulse modulation starts. The pulse delay is not effective for double pulse
generation.
Parameters:
<Delay> float
Range: 0 to 100 s
Increment: 10 ns
*RST: 10 ns
Default unit: s
Example:
PULM:DEL 13 us
13 us elapse after a trigger before the first pulse is generated.
Options: R&S SMB-K23 (Pulse Generator)
Manual operation: See "Pulse Delay - Pulse Generator" on page 196