Remote Control Commands
R&S
®
SMB100A
330Operating Manual 1407.0806.32 ─ 13
Example:
LIST:SEL '/var/user//Lists/Listmode/list3'
selects list3 for use in List mode.
LIST:IND:STAR 25
sets 25 as start index of the index range.
LIST:IND:STOP 49
sets 49 as stop index of the index range.
FREQ:MODE LIST
activates List mode. The frequency/level value pairs from index 25
to index 49 in list3 are processed. All other entries of the list are
ignored.
Manual operation: See "List Range In - List Mode" on page 164
[:SOURce<hw>]:LIST:LEARn
The command learns the selected list, i.e. it determines the hardware setting for the entire
list. The data determined in this way is stored together with the list. When the list is acti-
vated for the first time, these settings are calculated automatically.
Example:
LIST:SEL '/var/user//Lists/Listmode/list3'
selects list3. List3 is created if it does not yet exist.
LIST:LEAR
starts learning of the hardware setting for list3 and stores the set-
ting.
Usage: Event
Manual operation: See "Learn List Mode Data... - List Mode" on page 162
[:SOURce<hw>]:LIST:MODE <Mode>
The command specifies how the list is to be processed (similar to
SOURce:SWEep:MODE).
Parameters:
<Mode> AUTO | STEP
AUTO
Each trigger event triggers a complete list cycle. Possible trigger
settings for :LIST:TRIGger:SOURce are AUTO, SINGle and
EXT.
STEP
Each trigger event triggers only one step in the list processing
cycle. The list is processed in ascending order.
*RST: AUTO
Example:
LIST:MODE STEP
selects step-by-step processing of the list.
Manual operation: See "Mode - List Mode" on page 161