SIMOCODE pro
Index-14 GWA 4NEB 631 6050-22 DS 03
Index
binary) D-5
Thermistor motor protection with PTC
(binary) 1-13, D-5
Thermistor open circuit 15-8
Thermistor protection 1-15, 3-1, 3-2,
Glossary-16
Thermistor sensor 1-15
Thermistor short circuit 15-8
Thermistor trip level 15-8
Thermistors 3-15
Through-hole opening, current measuring
modules, current/voltage measuring
modules D-8
Through-hole openings 13-30, 13-31
Through-hole technology 1-24, 13-30,
13-31
Through-hole technology up to 200 A
13-30, 13-31
Tightening torques 13-12, 13-32
Time range for permissible starts 5-20
Time range for starts 5-20
Time stamp 1-92, 1-131
Time synchronization 10-26
Time synchronization via
PROFIBUS DP 1-20
Time to trip 1-22, 1-62
Timer 1-21, 1-69, 11-2, 11-10, 11-14
Timer - output 1-69
Timer 1 (2, 3, 4) 1-125
Timer actual value 1-69
Timer logic modules 11-10
Timestamping 1-20, 10-3, 10-26
Timestamping active 1-73
TM inputs 1-125
TN-C system Glossary-16
TN-S system Glossary-16
Torque 4-56
TPF 1-122
Transferring parameters to the basic
unit 2-9
Transformation ratio 13-33
Transformation ratio - active 3-5, 3-6
Transformation ratio - primary 3-6
Transformation ratio - secondary 3-6, 3-7
Trip - Bus 15-9
Trip - PLC/PCS 10-24, 15-9
Trip - Power failure (UVO) 10-16
Trip - Test position feedback (TPF) 10-9
Trip antivalence 15-8
Trip class 3-5, 3-8, F-4
Trip current 1-23
Trip end position 15-9
Trip temporary components 15-9
Tripping characteristic F- 4
Tripping temperature F-5
Tripping time
3-5, 3-8
T
ruth table 2I/1O 1-129, 11-6
Tr
uth table 3I/1O 1-129, 11-3, 11-5
Truth table 5I/2O 1-130, 11-7
Truth tables 1-21, 11-2, 11-4, 11-5
Type of load 3-11
Type of protection EEx e and EEx d F-2
Types of positioner control 4-56
Types of signals 11-16, 11-19
Types of signals/output responses of the
signal conditioners 11-16
U
U L1-L2, U L2-L3, U L3-L1 1-57,1-60, 1-76
UL1-N, UL2-N, UL3-N 1-57, 1-60, 1-76
Unbalance 15-5
Unbalance level 3-13
Unbalance monitoring 1-13
Unbalance protection 1-15, 3-1, 3-2, 3-13,
Glossary-17
Universal Current (UC) Glossary-17
USB to serial adapter 1-27, 1-107
UVO 1-128
UVO fault 10-15
V
Voltage display 1-83
Voltage in phases 1, 2 and 3 1-22
Voltage measurement 1-13, 1-76
Voltage monitoring 1-128
Voltage monitoring 1-16, 5-1, 5-8,
Glossary-17
Voltage monitoring for undervoltage 1-13
W
Warning level 0/4 - 20 mA > overshot
15-9
Warning level 0/4 - 20 mA< undershot
15-9
Warning level cos phi < 15-9
Warning level I< undershot 15-9
Warning level I> overshot 15-9
Warning level P< undershot 15-9
Warning level P> overshot 15-9
Warning level U< undershot 15-9
Warnings 1-52, 1-83
Warnings (OPD) 1-48
Warranty F- 9
Watchdog 1-20, 1-131, 10-2, 10-24, 10-25
Watchdog function block 10-24
Win SIMOCODE DP Converter 1-110
Win SIMOCODE DP converter
Glossary-17
Win SIMOCODE DP parameter files
1-110
Wiring 13-1, 13-12
Wiring the basic units, expansion modules
and the decoupling module 13-12

Table of Contents

Other manuals for Siemens SIMOCODE pro

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOCODE pro and is the answer not in the manual?

Siemens SIMOCODE pro Specifications

General IconGeneral
Protection ClassIP20
Mounting TypeDIN rail mounting
Rated Operational Voltage24 V DC
Rated CurrentUp to 820 A
Protection FunctionsOverload, short-circuit, phase failure, asymmetry, ground fault, motor stall
Operating Temperature Range-25°C to +60°C
Communication ProtocolsPROFIBUS DP, PROFINET, Modbus RTU
Analog OutputsUp to 2
Temperature MonitoringPTC/KTY, RTD (PT100/PT1000)
Digital OutputsRelay outputs, Solid-state outputs
Analog Inputs0/4-20mA, PT100/PT1000