SVAN 979 User Manual
Trigger Pulse
Functionality of the Digital Out I/O mode when digital
signal used for triggering other “slave instrument(s)” (the
instrument is acting in this case as a master
instrument”). One additional parameter is used for this
functionality of the Digital Out I/O mode: Polarisation.
Chapter
7.10
Appendix C
Polarisation
Parameter of the Digital Out I/O mode defining which
polarisation of the signal (Negative or Positive) will be
applied to the output trigger pulse.
Chapter
7.10
Appendix C
Alarm Pulse
Functionality of the Digital Out I/O mode when digital
signal is used as a source of alarm signal in case of
certain circumstances occurred during measurements
(i.e. the level of the input signal was higher than a user
selected trigger alarm setting). A set of additional
parameters are used for this functionality of the
Digital Out I/O mode: Active Level, Source,
Source Type, Alarm Level, Send SMS and Send E-mail.
Chapter
7.10
Appendix C
Active Level
Parameter, when Alarm Pulse is selected as a function
of the Digital Out I/O mode, defining the level of the
signal, treated as an alarm: Low (0 V) or High (3 V).
Chapter
7.10
Appendix C
Source
Parameter, when Alarm Pulse is selected as a function
of the Digital Out I/O mode, defining the measured result,
the level of which should be checked for alarm
generation. The measurement results from the first
profile: Peak(1), Spl(1), Max(1) or Leq(1) can be used.
Chapter
7.10
Source Type
Parameter, when Alarm Pulse is selected as a function
of the Digital Out I/O mode, defining the type of Source:
Current (measured with 1 second step) or Periodic
(measured with Integration Period step).
Chapter
7.10
Alarm Level
Parameter, when Alarm Pulse is selected as a function
of the Digital Out I/O mode, defining the threshold level
of the result to be monitored during the measurement. If
the result is greater than the alarm level, the instrument
will generate the alarm signal in the selected logic.
Chapter
7.10
Send SMS
Activation of alarm SMS sending via Wireless Transfer
when Alarm Pulse is selected as a function of the
Digital Out I/O mode.
Chapter
7.10
Send E-Mail
Activation of alarm e-mail sending via Wireless Transfer
when Alarm Pulse is selected as a function of the
Digital Out I/O mode.
Chapter
7.10