236
SVAN 979 User Manual - Appendixes
Word
number
Name
Comment
4
Source
triggering source (parameter relevant only for alarm pulse function in
digital output mode):
0 triggering by RMS/Leq level from the first profile
1 triggering by the Peak level from the first profile
2 triggering by max level from the first profile
3 triggering by P-P/Spl level from the first profile mode
5
SourceType
triggering type (parameter relevant only for alarm pulse function in
digital output mode)):
0 triggering condition checked every second (Current)
1 triggering condition checked after the end of the
measurement cycle (Periodic)
6
AlarmLevel
triggering threshold value in 0.01 dB format (parameter relevant only
to alarm function in digital output mode)
7
Polarisation/Slope
polarity of external triggering pulse (parameter relevant only to
instantaneous triggering pulse function):
0 positive polarity
1 negative polarity
active slope of external triggering pulse (essential for out-of-range
performance):
0 active positive slope
1 active negative slope
reserved
Table B.1.13. Main block of profile parameters
Word
number
Name
Comment
0
0nn05h
05h = block identifier
0nnh = block length in words
1
00nxxh
n = number of profiles, 0xxh = profile bit mask (bit mask informs which
parameter profiles are available)
2..
Profile[1]
inner block with identifier 06h containing parameters of the first profile
(if the first profile bit mask is set) see Table B.1.14
...
...
...
...
Profile[n]
inner block with identifier 06h containing parameters of the last profile
(if the bit mask of the last profile is set) see Table B.1.14