TH2829X Series Operation Manual Chapter 10 HANDLER
Command syntax: CORRection:USE:DATA?
Return format:
<open1 A>,<open1 B>,<short1 A>,<short1 B>,<load1 A>,<load1 B>,
<open2 A>,<open2 B>,<short2 A>,<short2 B>,<load2 A>,<load2 B>,
……
<open201 A>,<open201 B>,<short201 A>,<short201 B>,<load201
A>,<load201 B>,
Where,
<open1/2/……/201 A> is NR3 data format and the primary open correction data
at frequency spot 1/2/……/201.
<open1/2/……/201 B> is NR3 data format and the secondary open correction
data at frequency spot 1/2……/201.
<short 1/2/……/201 A> is NR3 data format and the primary short correction data
at frequency spot 1/2/……/201.
<short 1/2/……/201 B> is NR3 data format and the secondary short correction
data at frequency spot 1/2/……/201.
<load1/2/……/201 A> is NR3 data format and the primary load correction data at
frequency spot 1/2/……/201.
<load1/2/……/201B> is NR3 data format and the secondary load correction data
at frequency spot 1/2/……./201.
The CORRection:CLEar command is used to clear the correction data of all the
correction points.
Command syntax: CORRection:CLEar
9.1.15 COMParator subsystem commands
The COMParataor subsystem commands are used to set the bin comparator
function including ON/OFF setting, Limit table setting.
Command tree: