ENGINE
4-37TX525 Service Manual Rev. 000
Checking the Alternator Belt Tension
Fig 0211 g.EEAB...17B
1. Measurethedeection(A)bydepressingthebelt
halfwaybetweenthefandrivepulleyandalternator
pulleyatthespeciedforceof22lbs.(98N,10kgf).
2. Ifthemeasurementisnotwithinthefactoryspeci-
cations,loosenthealternatormountingscrewsand
relocatethealternatortoadjustandre-tightenthe
mountingscrews.
A. .28to0.35”(7.0to9.0mm)
A
Cooling Fan Replacement
1. Removetheradiatorandoilcoolerassembly.Refer
to“Radiator&OilCoolerAssemblyRemovalon
page4-1.
2. Usinga7/16”socket,removethe4boltsandlock-
washerssecuringthecoolingfantothefanmount
spacer(Fig.0212).
Fig 0212 PICT-5112a
Cooling Fan Removal