8-88
182582-1CD
182582-1CD
8 System Setup
8.7 Shock Detection Function
MH900, DX200 Controller
SHCKSET
1. Move the cursor to the immediately preceding line where the
SHCKSET instruction is to be registered.
2. Press [INFORM LIST].
The inform list dialog box is shown.
3. Select SHCKSET instruction.
(1) SHCKSET instruction is shown in the input buffer line.
(2) Change the value of additional item and numerical data.
(3) Press [INSERT] then [ENTER].
4. Change the value of additional item and numerical data.
< When registering the instruction as it is >
Operate the step 5 when registering the instruction in the input
buffer line as it is.
< When adding or changing the additional item >
• When changing the shock detection level
(1) When changing the shock detection level, move the cursor to the
shock detection level condition number; hold down [SHIFT] and
press the up/down cursor key to change the condition number.
• When the value is input with the numeric key
(1) When the value is input with the numeric key, press [SELECT] to
display the input buffer line.
(2) Press [ENTER] to change the number in the input buffer line.