8 System Setup
8.21Preventive Maintenance Function
8-177
182582-1CD
182582-1CD
MH900, DX200 Controller
=Torque
The minimum value and the maximum value of the vertical axis can be
set. “MIN” is the minimum value, and “MAX” is the maximum value.
=Axis
Removing the tick in the box hides the axis on the screen.
=Save CSV
Pressing the “CSV” button saves the variation and measured value into
the external memory device as CSV format. As for the external device, it
can be saved into both CF card and USB, but the data is priory save into
the CF card. The followings are the name for a file and a folder to be
saved.
File name: “the name which is set in the each setting window” + “year/
month/day” + ”hour/minute/second”. CSV
Folder name: “SR LIFE DIAGNOSIS”
=Hard COPY
Pressing the “=Hard COPY” button saves the hard copy of the screen as
JPG format into the CF card.
The following is a name for the file.
File name: “year/month/day” + “hour/minute/second”. JPG
=CLOSE
Pressing “=CLOSE” button closes the graph window.
8.21.2.3 After Replacement of the Speed Reducer
The lifetime diagnosis does not perform correctly if use the old data after
replacement of the speed reducer. Thus, reset the data for the lifetime
diagnosis, and prevent using the data before replacement day.
Perform the following procedures after replacement of the speed reducer.
1. Change the security mode to the management mode.
2. Select {=RM} in the main menu.
3. Select {=RM(REDUCER)}.