8-222
182582-1CD
182582-1CD
8 System Setup
8.23Safety Logic Circuit
MH900, DX200 Controller
Timer
Feedback Signal (Signal Name: GSEDM1, 2) of Universal Output Signal
The setting of whether to use or not to use the signal and the polarity
setting of the feedback signal (signal name: GSEDM1, 2) of the universal
output signal can be set in the following window.
1. Turn ON the power of controller while pressing “Main Menu” key of the
programming pendant.
2. Select {SYSTEM} - {SECURITY} and change the security mode to the
safety mode.
3. Select {SYSTEM} - {SETTING} - {OPTION FUNCTION} - {Machine
Safety function}. Then the following window appears and the setting
change becomes possible.
No. Signal Name Abbreviation Note
1 ON delay timer1 to ON
delay timer4
TIMI1 ON DELAY ~
TIM4 ON DELAY
The value set in the timer delay.
2 OFF delay timer1 to
OFF delay timer4
TIM1 OFF DELAY ~
TIM4 OFF DELAY