8-224
182582-1CD
182582-1CD
8 System Setup
8.23Safety Logic Circuit
MH900, DX200 Controller
Press [ENTER].
The confirmation dialog box of parameter change appears.
2. Select {YES}.
If {YES} is selected, the system parameter is set automatically, and
then the OPTION FUNCTION window appears.
Feedback Signal
(1) With feedback signal connection
69
70
(JANCD-YFC22-E)
(JANCD-YSF22-E)
CN219
DX200
GSOUT1_1-
GSOUT1_1+
71
72GSOUT1_2-
GSOUT1_2+
77
78GSEDM1-
GSEDM1+
Machine Safety I/O
Logic Circuit Board
Machine Safety Terminal
Block Circuit Board
Universal Safety Output 2
Universal Safety Output 1
Dual Sianals
Safety Signal
Intaken as a feedback signal(*) of the devices driven by
the universal safety output signal(GSOUT) (safety relay,
contactor, etc.), and detects the wire sticking.
(*) It connects the contact B with forced guide nomally.