8-258
182582-1CD
182582-1CD
8 System Setup
8.23Safety Logic Circuit
MH900, DX200 Controller
f. How to use MS-OUT signal
The following is the explanation to use MS-OUT signal.
1. Create the following safety logic circuit.
01 #1 GSIN1 MS-OUT01
2. When GSIN1 signal is turned ON, MS-OUT01 signal is turned ON.
3. The MS-OUT01 signal created in the safety logic circuit can be used
as a input signal, etc. to set each axis motion range in the functional
safety (optional function).
8.23.4.14 Saving or Loading the File
Refer to chapter 8.23.5 .
8.23.4.15 Alarm List of the Safety Logic Circuit
Refer to chapter 8.23.8 .