8 System Setup
8.23Safety Logic Circuit
8-271
182582-1CD
182582-1CD
MH900, DX200 Controller
5. Perform the initialization.
Select {ENTER}.
The confirmation dialog appears.
Select {YES}.
The file written in the FLASH ROM of the machine safety circuit
board (type: YSF21-E) is initialized.
8.23.6.2 Machine Safety Flash Data Erase or Reset
Erase the safety logic circuit file (file name: YSFLOGIC.DAT) written in the
FLASH ROM of the machine safety circuit board (type: YSF21-E) by
selecting “Machine Safety Board FLASH Erase”.
By selecting the “Machine Safety Board FLASH Reset”, the machine
safety circuit board (type: YSF21-E) is transferred and saved in the
FLASH ROM of the machine safety circuit board (type: YSF21-E).
Machine Safety Board FLASH Erase
1. Displaying the window.
Select {Machine Safety Board FLASH Erase} by going to
{INITIALIZE} from {FILE} in the man menu.