Loading...
9-19
182582-1CD
182582-1CD
9 System Backup
9.3 Automatic Backup Function
MH900, DX200 Controller
Window Settings
RS parameter can restrict the settings of some items in the automatic
backup window.
When setting the bit of RS096 parameter shown below to “1”, the
corresponding items are restricted. The restricted items are indicated with
“INVALID” in the display and inputting/modification to the item becomes
impossible. Also, the automatic backup does not function with the
restricted items.
Output the Backup Processing Status
Able to confirm the backup processing status by the system output signal.
<#50766> It is creating the auto backup data.
When this signal is turned ON, it is creating the backup data.
Some operations are limited. For example, the start signal is not accepted.
<#50767> It is transferring the backup data.
When this signal is turned ON, writes the data to the CompactFlash after
creating the backup data. Do not remove the CompactFlash from the
programming pendant during this period.
RESERVE TIME BACKUP
MODE CHANGE BACKUP
STARTUP BACKUP
RETRY CYCLE
DURING ALARM BACKUP
SPECIFIC INPUT BACKUP
D5 D4 D3 D2 D1 D0D6D7