EasyManua.ls Logo

YASKAWA DX200 - Page 451

YASKAWA DX200
552 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12-23
182582-1CD
182582-1CD
12 Modification of System Configuration
12.3Addition of Base and Station Axes
MH900, DX200 Controller
3. Therefore, when an overrun alarm occurs, the subcode is indicated by
the control group.
However, select “NOT CONNECT” if an overrun switch is not installed
to the control group or the allocation of the external axis overrun signal
is not needed.
Regarding the connection of the external axis overrun signal, refer to
chapter 14.7 “Universal I/O Circuit Board (JANCD-YIO21-E)” at
page 14-37.
4. Select a desired item.
5. Press [ENTER] in the CONNECT window.
The setting in the CONNECT window is completed and the window
moves to the AXES CONFIG window.
An error message Error 8217 Cannot change setting.
Check the setting of spot high speed spec.” may appear
when press [ENTER] in the CONNECT window.
When the error message appears, invalid SPOT HIGH
SPEED SPEC or review the configuration of the control
group by referring to section 9.12 High Speed Spot
Welding Function” at DX200 OPERATOR’S MANUAL FOR
SPOT WELDING USING MOTOR GUN.
451 of 552

Table of Contents

Other manuals for YASKAWA DX200

Related product manuals