14 Description of Units and Circuit Boards
14.6Machine Safety Terminal Block Circuit Board (JANCD-YFC22-E)
14-17
182582-1CD
182582-1CD
MH900, DX200 Controller
Wiring Procedure of the Terminal Block
For your safety, appropriate work must be done by following the
instructions below.
1. Tool: Screwdriver
For the connection, be sure to use a screwdriver of an applicable
size and configuration.
2. Applicable Wires
(1) The length of the exposed conductor (L) should be as follows:
* The length of the exposed conductor set for the terminal block (L)
WAGO series 250 (with 5.0 mm pitch): 9-10 mm
* Applicable max cable outside diameter: 3.1 mm dia.
(2) In case that the conductor is bent or feazed, make it straight as
illustrated in the figure above.
3. Wire Connection
(1) Place the screwdriver on the lever upright as shown in the figure
* WAGO standard screwdriver
WAGO 210-119
WAGO 210-119SB (Short,
delivered with the product)
L
Terminal block: screwless clamp
terminal WAGO series 250