YASKAWA TM.V1000.01 V1000 Drive Installation & Start-Up Manual (Preliminary 01-19-07) 5
4. START-UP PROGRAMMING & OPERATION .... 97
4.1 Safety Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
4.2 Using the Digital LED Operator . . . . . . . . . . . . . . 102
Keys, Displays, and LEDs . . . . . . . . . . . . . . . . . . . . . . . . 102
Digital Text Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
LED Screen Displays . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
LO/RE LED and RUN LED Indications . . . . . . . . . . . . . . 105
Menu Structure for Digital LED Operator . . . . . . . . . . . . 107
The Drive and Programming Modes . . . . . . . . . . . . . . . . 108
Navigating the Drive and Programming Modes . . . . . . . 109
Changing Parameter Settings or Values . . . . . . . . . . . . . 113
Verifying Parameter Changes: Verify Menu . . . . . . . . . . 114
Switching Between LOCAL and REMOTE . . . . . . . . . . . 115
Parameters Available in the Setup Group . . . . . . . . . . . . 117
4.3 Start-up Flowcharts . . . . . . . . . . . . . . . . . . . . . . .118
Flowchart A: Basic Start-Up Sequence . . . . . . . . . . . . . . 119
Flowchart B: V/F Motor Control Set-Up . . . . . . . . . . . . . 120
Flowchart C: Open Loop Vector Motor Control Set-Up . . 121
Flowchart D: Permanent Magnet Motor Control (PM) . . . 122
Flowchart E: Using Application-Specific Presets . . . . . . 123
4.4 Basic Parameter Adjustments . . . . . . . . . . . . . . . 124
Control Mode Selection . . . . . . . . . . . . . . . . . . . . . . . . . . 124
Initialize Parameter Values: A1-03 . . . . . . . . . . . . . . . . . 124
Drive Duty Mode and Carrier Frequency Selection . . . . 125
Drive Input Voltage Setting E1-01 . . . . . . . . . . . . . . . . . . 129
Frequency Reference Source: b1-01 . . . . . . . . . . . . . . . 130
Run Command Input Selection: b1-02 . . . . . . . . . . . . . . 133
Stopping Method Selection: b1-03 . . . . . . . . . . . . . . . . . 136
Acceleration/Deceleration C1-01 to C1-11 . . . . . . . . . . . 141
V/f Pattern Selection: E1-03 . . . . . . . . . . . . . . . . . . . . . . 143
Motor Parameters: E2-01 through E2-12
(Manually Entering Parameter Settings) . . . . . . . . . . . . 147
Drive Status Monitors: U1-01 to U6-19 . . . . . . . . . . . . . . 150
Analog Outputs: H4-01 to H4-03 . . . . . . . . . . . . . . . . . . . 153
Digital Outputs H2-01 to H2-03 . . . . . . . . . . . . . . . . . . . . 155

Table of Contents

Other manuals for YASKAWA V1000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA V1000 Series and is the answer not in the manual?

YASKAWA V1000 Series Specifications

General IconGeneral
ModelV1000 Series
SeriesV1000
Output Frequency0.1 to 400 Hz
Overload Capacity150% for 60 seconds
TypeAC Drive
Control MethodV/f Control
Input Voltage200-240V, 380-480V
Output Voltage0 to Input Voltage
Power Range0.1 to 18.5 kW
Horsepower0.2 to 25 HP
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overheating, Short Circuit, Ground Fault
Communication InterfacesModbus RTU
EnclosureIP20
Ambient Temperature-10 to +50°C
Storage Temperature-20 to +60°C
Humidity5 to 95% RH (non-condensing)
Cooling MethodFan Cooled