<3> Gauges listed here are for use in Europe and China.
<4> When an EMC filter is installed, additional measures must be taken to comply with IEC/EN 61800-5-1. Refer to EMC Filter Installation on
page 436 for details.
Note: Use crimp insulated terminals or insulated tubing for wiring these connections. Wires should have a continuous maximum allowable
temperature of 75 °C 600 V UL approved vinyl sheathed insulation. Ambient temperature should not exceed 30 °C.
Closed-Loop Crimp Terminal Recommendations
Yaskawa recommends crimp terminals made by JST and Tokyo DIP for the insulation cap. Table D.9 matches drives
models with crimp terminals and insulation caps. Orders can be placed with a Yaskawa representative or directly with the
Yaskawa sales department.
Table D.9 Closed-Loop Crimp Terminal Size
Drive Model
Wire Gauge AWG
Terminal
Screws
Crimp Terminal
Model No.
Tool
Insulation Cap
Model No.
Code
<2>
R/L1, S/L2,
T/L3
U/T1, V/T2,
W/T3
Machine No. Die Jaw
200 V Class Single-Phase Drives
BA0001
BA0002
BA0003
18
M3.5
R1.25-3.5
YA-4 AD-900 TP-003
100-066-217
16
14
<1>
R2-3.5 100-066-218
BA0006
14
<1>
M4
R2-4
YA-4 AD-900
TP-003 100-054-028
12
R5.5-4 TP-005 100-054-029
10
BA0010
14
14
<1>
M4
R2-4
YA-4 AD-900
TP-003 100-054-028
12
<1>
12
R5.5-4 TP-005 100-054-029
10 10
BA0012
14
14
<1>
M4
R2-4
YA-4 AD-900
TP-003 100-054-028
12 12
R5.5-4 TP-005 100-054-029
10
<1>
10
BA0018
12
12
<1>
M5
R5.5-5
YA-4
AD-900 TP-005 100-054-030
10 10
8
<1>
8 R8-5 AD-901 TP-008 100-054-032
200 V Class Three-Phase Drives
2A0001
2A0002
2A0004
2A0006
18
M3.5
R1.25-3.5
YA-4 AD-900 TP-003
100-066-217
16
14
<1>
R2-3.5 100-066-218
2A0008
2A0010
14
<1>
M4
R2-4
YA-4 AD-900
TP-003 100-054-028
12
R5.5-4 TP-005 100-054-029
10
2A0012
14
<1>
M4
R2-4
YA-4 AD-900
TP-003 100-054-028
12
R5.5-4 TP-005 100-054-029
10
2A0018
14
M4
R2-4
YA-4 AD-900
TP-003 100-054-028
12
<1>
R5.5-4 TP-005 100-054-029
10
2A0020
14 14
M4
R2-4
YA-4 AD-900
TP-003 100-054-028
12
12
<1>
R5.5-4 TP-005 100-054-029
10
<1>
10
2A0030
10 10
M4
R5.5-4
YA-4
AD-900 TP-005 100-054-029
8
8
<1>
8-4 AD-901 TP-008 100-054-031
6
<1>
6 14-4 AD-902 TP-014 100-066-220
2A0040
10
M4
R5.5-4
YA-4
AD-900 TP-005 100-054-029
8 8-4 AD-901 TP-008 100-054-031
6
<1>
14-4 AD-902 TP-014 100-066-220
D.3 UL Standards
YASKAWA ELECTRIC SIEP C710606 16C YASKAWA AC Drive – V1000 Technical Manual
445
D
Standards Compliance

Table of Contents

Other manuals for YASKAWA V1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA V1000 and is the answer not in the manual?

YASKAWA V1000 Specifications

General IconGeneral
Input Voltage3-Phase 200-240VAC, 3-Phase 380-480VAC
Output Voltage3-Phase 200-240VAC, 3-Phase 380-480VAC
Output Frequency0-400 Hz
Control MethodV/f control
Overload Capacity150% for 60 seconds
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overheating, Short Circuit, Ground Fault
Communication OptionsModbus RTU
Ambient Temperature-10 to +50°C (14 to 122°F)
Storage Temperature-20°C to +65°C (-4°F to 149°F)
Humidity95% (non-condensing)
Cooling MethodForced Air Cooling
EnclosureIP20

Related product manuals