7. Power Input
7.1 Replacing the input voltmeters fuse
WARNING: Disconnect the power cord from the projector and wait a few minutes (to discharge the capacitors)
prior to start with this procedure.
Necessary tools
•7mmat screwdriver.
•6mmat screwdriver
Necessary parts
Miniature Fuse, 5 x 20 mm, Time-Lag T, H, 250 VAC, UL: 115 V - 300 VDC.
Howtoreplacethefuseofthevoltmeter?
1. R emov e the back cover of the projector.
2. Open the fuse holder and pull out the fuse seating and fuse. Use a 6mm at screwdriver.
3. P lace a new fuse of 1A/250VAC in the fuse s eating.
4. Insert the fuse seating with new fuse in the fuse holder.
1
Image 7-1
R5905312 HDF W SERIES 24/01/2013 109