8. Lamp and lamp house
8.9 Cleaning the Reector of the Lamp House
When cleaning the Reector?
Only clean the Re ector of the Lamp House in case it is really necessary. This means in case dust is clearly visible upon the surface
of the Reector.
This procedure requires that the xenon lamp is removed from the Lamp House.
WARNING: ISOPROPANOL ALCOHOL (200–661–7).
Hazardous product. Irritating to eyes and skin. Always use in a well ventilated area. Vapors may cause drowsi-
ness and dizziness. Avoid contact with skin and eyes. In case of contact with the eyes, rinse immediately with
plenty of water and seek medical advise.
CAUTION: ISOPROPANOL ALCOHOL (200–661–7).
Hazardous product. Lightly ammable. Always use in a well ventilated area. Keep away from sources of
ignitions. Do not smoke while working with isopropanol. Exclusive keep in original container tightly closed
at a cool, well ventilated and reproof storage space.
Necessary tools
Compressed air.
Clean Toraysee® cloth.
Clean cotton cloth.
Demineralized water.
Isopropanol alcohol.
How to clean the Reector of the Lamp House?
1. Try to blow away the dust with com pressed air.
2. Is all dust removed from the R eec tor?
If yes, stop this cleaning procedure.
If no, wipe off the dust o f the Reector. Us e for that a clean Toraysee® cloth.
Tip: Limit the number of wipe mov ements. This to protect t he optical co ating. It is better to wipe of the dust w ith one good
wipe movement then with 10 soft wipe movements.
3. Is all dust removed from the R eec tor?
If yes, stop this cleaning procedure.
If no, wipe off the dust of the Reector rst w ith a clean cotton cloth and demineralized water and than with a clean Toraysee®
cloth.
Tip: Use isopropanol alcohol instead of demineralized water to remove ngerprints.
CAUTION: Never use a Lamp House which Reector is cracked or has a damaged coating. Neglecting this
will result in irreversible damage of the projector.
R5905312 HDF W SERIES 24/01/2013 137

Table of Contents

Other manuals for Barco HDF W series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Barco HDF W series and is the answer not in the manual?

Barco HDF W series Specifications

General IconGeneral
BrandBarco
ModelHDF W series
CategoryProjector
LanguageEnglish

Related product manuals