15. Liquid cooling circuit
15.3 Refreshing the liquid cooling circuit
Over time the cooling liquid may show deterioration and hence less effective cooling characteristics. To main-
tain sound cooling properties, we advise ANNUAL replacement of the cooling liquid.
Necessary tools
Half a m eter of plastic tube with male v alved tting.
Half a meter of plas tic tube with female valved tting.
Syringe equipped with male valved tting.
Female/female tube adapter (short tube with female v alved ttings at both sides).
Bottle with 1 liter cooling liquid.
Empty bottle with a volume of one liter.
•Cloths.
How to refresh the liquid cooling circuit ?
1. Interrupt the liquid cooling circuit by uncoupling the valved tting at t he heat exchanger.
1
2
Image 15-13
Uncouple heat exchanger
2. Insert the tube end of the plastic tube, which contains a female valved tting, into an em pty bo ttle and then couple the female
valved tting with the exit side of the cooling circuit.
Note: Circuit is p ressurized, so rst insert tube end into empty bottle.
R5905312 HDF W SERIES 24/01/2013
249

Table of Contents

Other manuals for Barco HDF W series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Barco HDF W series and is the answer not in the manual?

Barco HDF W series Specifications

General IconGeneral
BrandBarco
ModelHDF W series
CategoryProjector
LanguageEnglish

Related product manuals