2000X energy Power Supply Chapter 6: Operation
Instruction Manual Setting Primary Parameters
011-003-991 EN 6-25
Setting the Percentage of Peak Power
You can select the maximum percentage of available power that you want to be transmit-
ted to your part. When this power level is reached, ultrasonics will be terminated.
Take this action… To get this result…
Press the Select key that corresponds to
Peak Power (%).
Use the numeric keypad to enter the Peak
Power (as a percentage) that you want to
use, or press the same Select key repeat-
edly to toggle between the minimum value
(1%) and the maximum value (100%) for
Peak Power.
Press Enter on the numeric keypad to save
the new value, or press Go Back/Esc to
make no change to the value.
WELD SETUP Pg1of20
Weld Mode> Peak Power
Peak Power (%)= 100
Hold Time (s)= 0.010
WELD SETUP Pg1of20
Weld Mode> Peak Power
Peak Power(%) = 80
Hold Time (s) = 0.010
WELD SETUP Pg1of20
Weld Mode> Peak Power
Peak Power(%) = 80
Hold Time (s) = 0.010