Chapter 4: Installation and Setup
Installation Steps
4-20 011-003-991 EN
4.5.5 Interconnect between Power Supply and Actuator
Figure 4.9 Connections on Rear of Power Supply
The cable lengths are limited because of the amount and type of power and control being delivered to the
remainder of the system. Performance and results can suffer if the RF cable is crushed, pinched, damaged
or modified. Contact your Branson Representative if you have special cable requirements. In some cases,
remote operation from a User I/O or a Remote Terminal can be used to solve a distance limitation.
4.5.6 Input Power (Main)
The system requires single-phase input power, which you connect to the Power Supply using the
integral power cord. See “Table 4.4, Input Power Requirements” for plug and receptacle require-
ments for your specific power level.
Refer to the unit’s Model Data Tag to be sure of the power rating of the Model in your system.
4.5.7 Output Power (RF Cable)
Ultrasonic Energy is delivered to a screw-on receptacle connection on the rear of the Power Supply, which
is connected to the Actuator or the Converter (depending on your application).