2000X energy Power Supply Chapter 6: Operation
Instruction Manual System Menus
011-003-991 EN 6-7
6.3 System Menus
6.3.1 Using the Run Screen
The Run Screen is a set of information displayed on the 2000X Power Supply; it shows weld status, alarms,
weld count, and process information. The Run Screen appears as shown below.
The first line of the Run Screen shows current welding mode and value of the main parameter. For example,
on the Run Screen shown above, the weld mode is Time Mode and the Time is set to 30 seconds.
From the Run Screen you can observe the status of a weld cycle while it is in process. The first line cycles
through the following Weld States during a weld cycle.:
• READY indicates that the welder is ready to start a new cycle.
• EXTENDING indicates that the actuator is approaching your part.
• VERIFYING PRESET is verifying the preset you are using and the settings associated with it. This state
is only displayed on the first cycle after you change a parameter.
• EXTENDING indicates that the horn is in its down stroke.
• WELDING indicates that ultrasonics are on.
• HOLDING indicates that ultrasonics have turned off and pressure remains on your part. This shows only
if this parameter is turned on.
9 On the Power Supply front panel, press the Run key.
10
Activate both Start Switches simultaneously, or activate your Start Signal if you are using
the system in automation.
11
When the weld cycle is complete, and if the cycle has completed successfully, the cycle
counter increments to show a completed cycle. The top line of the Run screen displays:
RUN:XXX= whether or not the cycle was successfully completed.
If the Reset LED on the Power Supply front panel flashes and the second line displays an
alarm message, the test did not complete successfully. See Section 7.5 Troubleshooting,
beginning on page 7-12, for information on alarm conditions and how to correct them.
RUN: TIME =30.000
Preset1 ABCDE123456
Adjust Weld>
Weld Results>
RUN: TIME =30.000
VERIFYING PRESET
EXTENDING
WELDING
HOLDING
AFTERBURST DELAY
AFTERBURST
POST SEEKING
RETRACTING
PRINTING
RUN: TIME =30.000