Chapter 4: Installation and Setup
Installation Steps
4-22 011-003-991 EN
4.5.8 Interconnect between Power Supply and Actuator
If using a Branson 2000-series Actuator, there are two electrical connections between the Power Supply
and the Actuator: the RF Cable and the Actuator Interface cable. A 37-pin cable is used for Power and Con-
trol Signalling between the 2000 X ea Power Supply and a Branson Actuator. The cable connects to the rear
of the Power Supply and the rear of the Actuator. Refer to Figure 4.9 for clarification of connections on rear
of power supply.
For ground detect use, to have ultrasonic energy turn off when the horn comes in contact with your
electrically isolated fixture or anvil, it is necessary to install Branson cable EDP No. 100-246-630
from the MPS/GDS receptacle on the rear of the actuator to your isolated fixture/anvil in order to
utilize this feature.
There can be other connections to the Actuator, and other connections to the Power Supply, but these are
the only two standard connections, depicted in figure 4.11.