2000X energy Power Supply Chapter 7: Maintenance
Instruction Manual Parts Replacement
011-003-991 EN 7-51
7.7 Parts Replacement
The 2000X Power Supply contains components that can be degraded or damaged by elec-
trostatic discharge. Always use a Grounded Wriststrap and use a grounded work area when
handling or servicing the 2000X Power Supply.
In the following paragraphs, you are provided instructions on removing and replacing compo-
nents. Before you begin to disassemble any parts of the Power Supply, ensure that the Power
Supply is turned off, and the main power is disconnected. After the Power Supply cover is
removed, wait at least two minutes to allow capacitors to discharge. When necessary, refer
to Figure 7.3 Exploded View of all 2000 Modules and Figure 7.4 Front Panel, Exploded Parts
View to help you with these procedures.
The 2000X Power Supply is designed for a long service life. In the event the system malfunctions, many of
the internal components (Modules) are replaceable as a unit. If a particular module has failed, it should be
replaced or repaired at a Branson Depot Facility.
The 2000 system is designed with an extensive Alarms Message system. Refer to the list of error messages
to assist your troubleshooting. These error codes are described in Section 7.4, Troubleshooting, beginning
on page 6-10.
The following parts are replaceable. Refer to the following exploded view of the Power Supply to see the
location of each of these components or modules.
7.7.1 Power Supply Cover
The Cover is held in place with seven screws, three on each side of the case and one on the rear. Lift the
rear of the cover up to remove it. The Cover must be in place when the system is operating due to fan-forced
ventilation design. See Figure 7.3, Exploded View of all 2000 Modules for a view of the Cover.