Chapter 5: Technical Specifications
Technical Specifications
5-2 011-003-991 EN
5.1.2 Electrical Requirements
The following tables list input voltage and current requirements for the 2000X Welding System, and includes
power required when it is used with Branson 2000X-series Actuators.
Table 5.2 Electrical Input Operating Voltages
* This unit is rated at a 25% duty cycle with 5 second On time, 2000W continuous. Rated power is 4000W
at 40°C.
Table 5.3 Input Current and Fuse Requirements
Cycle Rate – up to 200 cpm. Cycle rate including off time is application and stack dependent.
Power Supply Rating Nominal Input Operating Voltage, +/-10%
40 kHz / 400 W 100-120, 200- 240 V, 50/60 Hz, Single Phase
40 kHz / 800 W 100-120, 200- 240 V, 50/60 Hz, Single Phase
30 kHz / 750 W 100-120, 200- 240 V, 50/60 Hz, Single Phase
30 kHz/1500 W 100-120, 200- 240 V, 50/60 Hz, Single Phase
20 kHz / 1125 W 100-120, 200- 240 V, 50/60 Hz, Single Phase
20 kHz / 2500 W 200- 240 V, 50/60 Hz, Single Phase
20 kHz / 3300 W 200- 240 V, 50/60 Hz, Single Phase
20 kHz / 4000 W* 220 - 253 V, 50/60 Hz Single Phase
For 20 kHz models
1250 W 200V - 240V 7 Amp Max. @ 200V / 20 Amp fuse
1250 W 100V - 120V 13 Amp Max. @ 100V / 20 Amp fuse
2500 W 200V - 240V 13 Amp Max. @ 200V / 20 Amp fuse
3300 W 200V - 240V 19 Amp Max. @ 200V / 20 Amp fuse
4000 W 220V - 240V 21 Amp Max. @ 220V / 25 Amp fuse
For 30 kHz models
750 W 100V - 120V
750 W 200V - 240V
1500 W 100V - 120V 20 Amp Max. @ 100V / 20 Amp fuse
1500 W 200V - 240V 10 Amp Max. @ 200V / 20 Amp fuse
For 40 kHz models
400 W 200V - 240V 3 Amp Max. @ 200V / 20 Amp fuse
400 W 100V - 120V 5 Amp Max. @ 100V / 20 Amp fuse
800 W 200V - 240V 5 Amp Max. @ 200V / 20 Amp fuse
800 W 100V - 120V 10 Amp Max. @ 100V / 20 Amp fuse