2000X energy Power Supply Chapter 7: Maintenance
Instruction Manual System Alarm Tables
011-003-991 EN 7-15
External Switch External Switch The external input is either
improperly configured, in
the wrong condition, or
failed.
Reconfigure properly, replace, or set
proper condition.
2000a
2000dt
2000e
2000t
Horn Return Timeout Horn Return Timeout The Horn did not retract to
the home position after the
weld was completed and
within the correct time. The
Horn might be jammed or
air pressure might have
failed. The Upper Limit
Switch might also have
failed.
Verify that air pressure is correct.
Check for obstructions or jams that
would prevent the Horn from
returning. Verify the operation of the
Upper Limit Switch.
2000a
2000dt
2000e
2000t
P/S NovRam Power Supply
NovRam Failed
The power supply NovRam
failed. It is checked only at
power up.
Repair/replace Control Board.
2000a
2000dt
2000e
2000t
Preset Data/BBR Failure of Preset
Data or Battery
Backed RAM
Corrupted data in
preset. Checked at power
up.
Replace BBR or repair/replace the
Control Board.
Replace battery.
2000a
2000dt
2000e
2000t
Pretrigger Timeout Pretrigger Timeout Pretrigger has not occurred
within 10
seconds of carriage leaving
home (of upper limit
becoming inactive).
Check the distance setting for
pretrigger to be sure the carriage is
traveling at least that far.
Repair/replace Control Board.
2000a
2000dt
2000e
2000t
Printer Buffer Full [No message sent to
printer.]
Your printer buffer is full and
no more data can be sent to
your printer.
Verify that the printer is online and
operational and wait until some data
has been printed.
2000a
2000dt
2000e
2000t
Printer Offline [No message sent to
printer.]
Your printer is offline or not
connected.
Verify that the printer is online and
operational and that connections are
maintained.
2000dt Recalibrate Actuator
Error Code = 100
Recalibrate Actuator Either the Actuator serial
number is different from the
last time power was turned
on, or your new setup
requires a calibration.
Run an Actuator Calibration
procedure from the Alarm Information
screen or from Calibrate in the Main
Menu.
Table 7.5 Failure of Alarms and Messages, with Probable Cause
and Corrective Action (Continued)
Model
Display
Message
Printer Message
Alarm Condition/
Cause
Corrective Action