Chapter 7: Maintenance
System Alarm Tables
7-20 011-003-991 EN
Model
Display
Message
Printer Message Alarm Condition/Cause Corrective Action
2000dt Abs Before Trg Absolute Distance
Before Trigger
The absolute distance has been
reached before trigger. This
alarm in other modes means the
absolute cutoff distance has
been reached before trigger.
Reset your absolute
distance parameter through
the Alarm Information
screen or the Setup menu.
2000a
2000dt
Amp Step Before Trg Amp Step Before
Trigger
The amplitude step trigger has
been detected within 2 ms of
start of weld time.
Reset your amplitude step
parameter through the
Alarm Information screen or
the Setup menu.
Table 7.6 No Cycle Alarms and Messages, with Probable Cause
and Corrective Action (Continued)
Model
Display
Message
Printer Message Alarm Condition/Cause Corrective Action