S0802190K
Page 27
Electrical System
Return to Master Table of Contents
Characteristic of Operation
Input Output
1 When starter switch is "ON."
All indicator lights are
turned on and turned off
after 2 - 2.5 seconds. At
this time the warning
buzzer will sound.
2
When "I" terminal voltage of
alternator.
is below 12 ±1 V.
Charging light, L5, will
be "ON."
is above 12 ±1 V.
Charging light, L5, will
be "OFF."
3
When "I" terminal voltage of
alternator is above 12 ±1 V.
Engine oil pressure switch is "ON."
Warning buzzer sounds
after 8 ±1 seconds.
Coolant temperature switch is "ON."
Warning buzzer sounds
immediately.
Brake oil pressure switch is "ON."
Warning buzzer sounds
immediately.
Forward and reverse lever switch is
"ON" and parking brake pressure
switch is "ON."
Warning buzzer sounds
immediately.